Oxifree application training
This is an example of a HTML caption with a link.

Polymelt 50 Atex 2-22 Application Machine

The Polymelt 50 ATEX 2-22 was designed to offer the following advantages:

  • Greater levels of sustained working application of the Oxifree TM198 material
  • Work in ATEX Zone 2-22 environments
  • The machines have been designed to go in a handy transport and storage trolley
  • The 50lb machine features a remote control unit to control flow pressure and pump operation at point of
  • application
  • Machines can operate all day, but do not require removal of material or cleaning when finished
  • Pressurised and purged enclosure with automatic siren and beacon to warn of any purge loss for use in hazardous environments

Operating Temperature: Oxifree_Polymelt_50
10 to 218C / 50 to 425F

Melt Rate (per hour):
10kg/hr / 23Kg/hr / 50lb/hr

Melt Rate (per hour) w/ Option Grid
41Kg/hr / 90lb/hr

Pump Rate per minute:
Piston / 10cc Gear = 1.8Kg / 4lb

Piston Pump Compression Ratios:
12:1

Gear Pump:
10cc

Hose Output Zones:
1

Maximum Working Hydraulic Pressure:
68 bar (1000psi)

Temperature Control Stability:
±1c / 1F

Electrical Service Standard:
240 VAC 1 Phase or 3 Phase 50/60Hz
380 VAC 3Phase Y 50/60 Hz (Optional)

Working Viscosity:
500-50,000 cps



Dimensions of Machine mounted in purge enclosure  trolley

Height (H):
109cm / 43in

Depth (D):
121cm / 48in

">Width (W):
96.5cm / 38in

Weight (Empty):
173kg / 380lbs

Hose Length:
34ft standard



ATEX Zone 2-22 Safety specifications

Purge System
1⁄2 Inch NPT air fitting,
Manufactured to EN60079-0, EN60079-2, EN61241-0, EN61241-4 standards

Purge rate (initial enclosure pressurization)
9-10cfm @ 60psi

Enclosure construction
IP66 rated stainless steel with anti static wheels, EX Standards: EN60079-18, EN60079-11
FM Pressurized electrical equipment for use in Hazardous locations Class 3000, Class 3620
UL Certified: PURGING AND PRESSURIZING CONTROLS AND
ACCESSORIES FOR USE IN HAZARDOUS LOCATIONS
(RFPW,RFPW7)

Pressure release rate
7-10psi per minute

Audible and visible warnings
Purge loss Alarm siren and flashing beacon

Electrical
EN670079-10, EN61241-10, ATEX CAT 3G and 3D Compliant

Manual override
Key operated